Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.798
Filtrar
2.
BMC Musculoskelet Disord ; 25(1): 330, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664811

RESUMO

BACKGROUND: The term 'physiological motion of the spine' is commonly used although no proper definition exists. Previous work has revealed a consistent sequence of cervical segmental contributions in 80-90% of young healthy individuals. Age has been shown to be associated with a decreased quantity of motion. Therefore, it is of interest to study whether this sequence persists throughout aging. The aim of this prospective cohort study is to investigate if the consistent sequence of cervical segmental contributions in young asymptomatic individuals remains present in elderly asymptomatic individuals. METHODS: In this prospective cohort study, dynamic flexion to extension cinematographic recordings of the cervical spine were made in asymptomatic individuals aged 55-70 years old. Individuals without neck pain and without severe degenerative changes were included. Two recordings were made in each individual with a 2-to-4-week interval (T1 and T2). Segmental rotation of each individual segment between C4 and C7 was calculated to determine the sequence of segmental contributions. Secondary outcomes were segmental range of motion (sRoM) and sagittal alignment. RESULTS: Ten individuals, with an average age of 61 years, were included. The predefined consistent sequence of segmental contributions was found in 10% of the individuals at T1 and 0% at T2. sRoM and total range of motion (tRoM) were low in all participants. There was no statistically significant correlation between sagittal alignment, degeneration and sRoM in the respective segments, nor between cervical lordosis and tRoM. CONCLUSIONS: This study shows that aging is associated with loss of the consistent motion pattern that was observed in young asymptomatic individuals. The altered contribution of the cervical segments during extension did not appear to be correlated to the degree of degeneration or sagittal alignment. Trial registration clinicaltrials.gov NCT04222777, registered 10.01.2020.


Assuntos
Envelhecimento , Vértebras Cervicais , Amplitude de Movimento Articular , Humanos , Pessoa de Meia-Idade , Vértebras Cervicais/diagnóstico por imagem , Idoso , Masculino , Feminino , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Envelhecimento/fisiologia , Fluoroscopia/métodos , Estudos de Coortes
3.
Sci Rep ; 14(1): 9475, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658572

RESUMO

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Assuntos
Osteotomia , Doses de Radiação , Exposição à Radiação , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto Jovem , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Luxação do Quadril/prevenção & controle , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Criança
4.
Sci Rep ; 14(1): 9406, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658695

RESUMO

This retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients' medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm2. Balloon dilation was performed in 77 patients. Total procedure time was 9.2 ± 7.6 min, and the mean procedure time without balloon dilation was 7.1 ± 5.7 min. Fluoroscopy-guided urethral catheterization is a safe and efficient alternative in patients where blind or cystoscopy-assisted urethral catheterization has failed or when cystoscopy-urethral catheterization cannot be performed.


Assuntos
Cistoscopia , Estreitamento Uretral , Cateterismo Urinário , Humanos , Fluoroscopia/métodos , Cistoscopia/métodos , Cistoscopia/efeitos adversos , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Estreitamento Uretral/terapia , Estreitamento Uretral/diagnóstico por imagem , Cateterismo Urinário/métodos , Cateterismo Urinário/efeitos adversos , Idoso de 80 Anos ou mais , Uretra/diagnóstico por imagem , Uretra/cirurgia
5.
J Clin Neurosci ; 123: 118-122, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38569382

RESUMO

Epidural blood patch (EBP)-the most effective treatment for intracranial hypotension (IH)-can be performed using the blind technique in the lateral position or under fluoroscopic guidance in the prone position. This study aimed to compare the effectiveness of EBP in patients with spontaneous intracranial hypotension (sIH) and iatrogenic intracranial hypotension (iIH) when performed with the blind technique in the lateral decubitus position or fluoroscopic guidance in the prone position. We reviewed IH patients who underwent EBP between January 2015 and September 2019 in a single hospital and divided them into two groups according to the type of IH. Of the 84 included patients, 36 had sIH and 48 had iIH. We compared the effectiveness of EBP using the two methods in each group. There was no significant difference in the effect of EBP between the patients with iIH (p > 0.05). For patients with sIH, fluoroscopic guidance in the prone position technique showed better improvement than the blind technique in the lateral decubitus position (p < 0.05). We observed similar outcomes after blind EBP versus fluoroscopic guidance EBP in patients with iIH. However, procedure-dependent differences were observed in patients with sIH. For patients with sIH, it would be effective to consider fluoroscopic EBP first. Further study is needed to investigate interactions between method of EBP and other factors that affect the effectiveness of EBP.


Assuntos
Placa de Sangue Epidural , Hipotensão Intracraniana , Humanos , Placa de Sangue Epidural/métodos , Hipotensão Intracraniana/terapia , Hipotensão Intracraniana/diagnóstico por imagem , Feminino , Masculino , Fluoroscopia/métodos , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Posicionamento do Paciente/métodos , Idoso
6.
Agri ; 36(2): 120-122, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38558396

RESUMO

Hip osteoarthritis (OA) is found in approximately 10% of the population and often causes disability and social limitations in elderly patients. Intra-articular injections are among the most frequently applied interventional treatments for the hip joint. Femoral and obturator sensorial nerve blocks have also been reported to be effective for both diagnostic and therapeutic purposes. A single needle insertion was performed for the blockage of the hip joint and sensory branches. For the sensory branch of the femoral nerve, the needle is advanced at nearly a 45-degree angle toward below the anterior inferior iliac spine near the anterolateral edge of the hip joint. For the sensory branch of the obturator nerve, the needle is advanced at nearly an angle of 45 degrees toward the area below the junction of the pubis and ischium. Finally, for joint injection, the same needle was advanced toward the midline of the anterior femoral head-neck junction at a steeper angle, and blocks were applied. Three patients with hip osteoarthritis were injected with this method and well-being was achieved in a 3-month follow-up. We think that blockage of the hip joint and peripheral sensory branches with a single needle insertion is a fast and effective method. However, prospective controlled studies are needed to determine the efficacy and safety of the method.


Assuntos
Osteoartrite do Quadril , Humanos , Idoso , Osteoartrite do Quadril/tratamento farmacológico , Estudos Prospectivos , Articulação do Quadril , Fluoroscopia , Injeções Intra-Articulares/métodos
7.
J Laparoendosc Adv Surg Tech A ; 34(4): 305-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573163

RESUMO

Introduction: Percutaneous endoscopic biliary lithectomy (PEBL) can be performed through preexisting drain tracts, offering ductal clearance and definitive management for patients with complicated gallstone disease unable to undergo conventional therapy. The technique has not been widely adopted by general surgeons. Herein, we describe our technique with surgeon-performed PEBL and present initial results. Materials and Methods: A single institutional retrospective review of the electronic medical record was performed for patients who underwent percutaneous choledochoscopy between February 2019 and November 2020. All operations were performed by 1 of 2 board-certified general surgeons with fellowship training in surgical endoscopy. Preoperative, operative, and postoperative variables were analyzed using descriptive statistics. Results: Thirteen patients underwent PEBL. Seventeen total procedures were performed; 4 patients underwent repeat intervention. The diagnoses leading to PEBL were: cholelithiasis (8), choledocholithiasis (4), and recurrent pancreatitis (1). Complete ductal clearance was achieved in 9 patients (69.2%) during the initial procedure. The remaining 4 patients (30.8%) underwent repeat PEBL, at which point complete ductal clearance was then achieved. The percutaneous drain was removed at the time of final procedure in 5 patients (38.5%) or within 5 weeks in the remaining 8 (61.5%). No intraoperative complications occurred, and no pancreatic or biliary postoperative complications or recurrences were noted with a mean follow-up of 279 ± 240 days. Conclusion: Surgeon-performed PEBL is a safe and effective method of achieving biliary ductal clearance. The technique is readily achieved following basic endoscopic and fluoroscopic principles and should be understood by all physicians managing gallstone disease.


Assuntos
Coledocolitíase , Cirurgiões , Humanos , Endoscopia , Fluoroscopia , Ductos Biliares
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 398-404, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632057

RESUMO

Objective: To explore the effectiveness of irreducible intertrochanteric femoral fracture in the elderly by treating with folding top technique and right-angle pliers prying and pulling under G-arm X-ray fluoroscopy. Methods: The clinical data of 74 elderly patients with irreducible intertrochanteric femoral fracture admitted between February 2016 and December 2022 and met the selection criteria were retrospectively analyzed. Among them, 38 cases were treated with folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy and intramedullary nailing fixation (study group), and 36 cases were treated with limited open reduction combined with other reduction methods and intramedullary nailing fixation (control group). There was no significant difference in baseline data between the two groups, such as age, gender, cause of injury, affected side and classification of fractures, complicated medical diseases, and time from injury to operation ( P>0.05). The operation time, intraoperative blood loss, hospital stay, fracture reduction time, fracture healing time, and complications of the two groups were recorded and compared. The quality of fracture reduction was evaluated by Baumgaertner et al. and Chang et al. fracture reduction standards. Results: Patients in both groups were followed up 10-14 months, with an average of 12 months. The operation time and intraoperative blood loss in the study group were significantly less than those in the control group ( P<0.05), there was no significant difference in hospital stay between the two groups ( P>0.05). At 2 days after operation, according to the fracture reduction standards of Baumgaertner et al. and CHANG Shimin et al., the quality of fracture reduction in the study group was better than that in the control group, and the fracture reduction time in the study group was shorter than that in the control group, with significant differences ( P<0.05). After operation, the fractures of the two groups all healed, and there was no significant difference in healing time between the two groups ( P>0.05). During the follow-up, there was no complication such as incision infection, internal fixation failure, deep venous thrombosis of lower limbs, intramedullary nail breakage, spiral blade cutting, or hip varus in the two groups, except for 2 cases of coxa vara in the control group. Conclusion: For the irreducible intertrochanteric femoral fracture, using folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy can obviously shorten the operation time, reduce the intraoperative blood loss, and improve the quality of fracture reduction.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Idoso , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Raios X , Resultado do Tratamento , Pinos Ortopédicos , Fraturas do Quadril/cirurgia , Fluoroscopia , Consolidação da Fratura
9.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 179-183, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605618

RESUMO

Objective: To introduce a locating device for the entry point of intramedullary nail based on the inertial navigation technology, which utilizes multi-dimensional angle information to assist in rapid and accurate positioning of the ideal direction of femoral anterograde intramedullary nails' entry point, and to verify its clinical value through clinical tests. Methods: After matching the locating module with the developing board, which are the two components of the locating device, they were placed on the skin surface of the proximal femur of the affected side. Anteroposterior fluoroscopy was performed. The developing angle corresponding to the ideal direction of entry point was selected based on the X-ray image, and then the yaw angle of the locating module was reset to zero. After resetting, the locating module was combined with the surgical instrument to guide the insertion angle of the guide wire. The ideal direction of entry point was accurately located based on the angle guidance. By setting up an experimental group and a control group for clinical surgical operations, the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss with or without the locating device was recorded. Results: Compared to the control group, the experimental group showed significant improvement in the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss, with a statistically significant difference (P<0.01). Conclusion: The locating device can assist doctors in quickly locating the entry point of intramedullary nail, effectively reducing the fluoroscopy frequency and surgical time by improving the success rate of the guide wire insertion with one shot, improving surgical efficiency, and possessing certain clinical value.


Assuntos
Fixação Intramedular de Fraturas , Cirurgia Assistida por Computador , Humanos , Pinos Ortopédicos , Perda Sanguínea Cirúrgica , Fluoroscopia/métodos , Fixação Intramedular de Fraturas/métodos , Cirurgia Assistida por Computador/métodos
10.
Ugeskr Laeger ; 186(14)2024 Apr 01.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38606703

RESUMO

Bronchoscopy has a low risk of complications when diagnosing peripheral lung lesions suspected of malignancy, however the procedures do not always determine a diagnosis. Several modalities have been invented to improve the diagnostic yield, including radial endobronchial ultrasound and electromagnetic navigation, which are currently used by several departments in Denmark. Augmented fluoroscopy, CT-guided bronchoscopy and robotic bronchoscopy are not yet available in Denmark, but may improve the diagnostic work-up, as argued in this review.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Broncoscopia/métodos , Fluoroscopia/métodos , Endossonografia/métodos , Pulmão/patologia
11.
Sci Rep ; 14(1): 9272, 2024 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653756

RESUMO

The transpedicular procedure has been widely used in spinal surgery. The determination of the best entry point is the key to perform a successful transpedicular procedure. Various techniques have been used to determine this point, but the results are variable. This study was carried out to determine the posterior endpoint of the lumbar pedicle central axis on the standard anterior-posterior (AP) fluoroscopic images. Computer-aided design technology was used to determine the pedicle central axis and the posterior endpoint of the pedicle central axis on the posterior aspect of the vertebra. The standard AP fluoroscopic image of the lumbar vertebral models by three-dimensional printing was achieved. The endpoint projection on the AP fluoroscopic image was determined in reference to the pedicle cortex projection by the measurements of the angle and distance on the established X-Y coordinate system of the radiologic image. The projection of posterior endpoint of the lumbar pedicle central axis were found to be superior to the X-axis of the established X-Y coordinate system and was located on the pedicle cortex projection on the standard AP fluoroscopic image of the vertebra. The projection point was distributed in different sectors in the coordinate system. It was located superior to the X-axis by 18° to 26° at L1, while they were located superior to the X-axis by 12° to 14° at L2 to L5. The projections of posterior endpoints of the lumbar pedicle central axis were located in different positions on the standard AP fluoroscopic image of the vertebra. The determination method of the projection point was helpful for selecting an entry point for a transpedicular procedure with a fluoroscopic technique.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Masculino , Feminino , Fusão Vertebral/métodos , Impressão Tridimensional , Desenho Assistido por Computador
12.
Rev. esp. cardiol. (Ed. impr.) ; 77(4): 332-341, abr2024. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-232195

RESUMO

Introducción y objetivos: El implante de stent es el tratamiento de elección en niños mayores y adultos con coartación aórtica (CoA). El objetivo fue determinar la incidencia de eventos tardíos después del tratamiento con stent. Métodos: Se analizó una cohorte de pacientes con CoA tratados en el centro entre 1993 y 2018 a los que se siguió periódicamente, incluyendo evaluación mediante tomografía computarizada (TC) y fluoroscopia. Resultados: Se incluyó a 167 pacientes con TC y fluoroscopia: 83 (49,7%) ≤ 12 años y 46 (28%) mujeres. El tiempo medio de seguimiento clínico fue de 17±8 años (rango 4-30) y de 11±7 años hasta la TC/fluoroscopia. Se detectó aneurisma en un 13% y se asoció al stent PALMAZ (OR=3,09; IC95%, 1,11-9,49; p=0,036) y a la longitud del stent (OR=0,94; IC95%, 0,89-0,99; p=0,039). La fractura del stent fue frecuente (34%) pero no asociada a la presencia de aneurisma. Se asoció con edad joven (OR=3,57; IC95%, 1,54-8,33; p=0,003), sexo masculino (OR=4,00; IC95%, 1,51-12,50; p=0,008) e inversamente con el stent PALMAZ (OR=0,29; IC95%, 0,12-0,67; p=0,005). La reintervención fue menor en adultos (10%), principalmente por aneurismas. Los pacientes que recibieron tratamiento cuando tenían 12 años o menos presentaron tasas de reintervención más altas (43%) debido al crecimiento somático. Conclusiones: Se observó una incidencia notable de eventos tardíos a largo plazo en pacientes con CoA tratados mediante stent. La reintervención fue más frecuente en pacientes tratados a edades más jóvenes. Parece aconsejable una vigilancia periódica mediante pruebas de imagen. (AU)


Introduction and objectives: Stent implantation is the preferred treatment in older children and adults with aortic coarctation (CoA). We aimed to determine the incidence of very late events after CoA stenting. Methods: We analyzed a cohort of CoA patients who underwent stent implantation at our center between 1993 and 2018. Patients were periodically followed up in outpatient clinics, including computed tomography (CT) and fluoroscopy assessment. Results: A total of 167 patients with CT and fluoroscopy data were included: 83 (49.7%) were aged ≤ 12 years and 46 (28%) were female. The mean clinical follow-up time was 17±8 (range 4-30) years and the mean time to CT/fluoroscopy was 11±7 years. Aortic aneurysm was present in 13% and was associated with the PALMAZ stent (OR, 3.09; 95%CI, 1.11-9.49; P=.036) and the stented length (OR, 0.94; 95%CI, 0.89-0.99; P=.039). Stent fracture was frequent (34%), but was not related to the presence of aneurysm. Stent fracture was associated with young age (OR, 3.57; 95%CI, 1.54-8.33; P=.003), male sex (OR, 4.00; 95%CI, 1.51-12.5, P=.008) and inversely with the PALMAZ stent (OR, 0.29; 95%CI, 0.12-0.67, P=.005). Reintervention was lower in adults (10%), mainly related to aneurysms. Those treated when aged ≤ 12 years had higher reintervention rates (43%) due to recoarctation somatic growth. Conclusions: This long-term follow-up study of CoA patients treated with stenting revealed a significant incidence of late events. Reintervention rates were higher in patients treated at younger ages. Periodic imaging surveillance appears to be advisable. (AU)


Assuntos
Humanos , Coartação Aórtica , Cardiopatias Congênitas , Aneurisma , Stents , Tomografia Computadorizada por Raios X , Fluoroscopia
13.
J. Am. Coll. Cardiol ; 83(13 Suppl. A)Apr. 2024. tab.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1551803

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) has improved catheter ablation procedures, reducing reliance on fluoroscopy. Yet, the efficacy and safety of zero-fluoroscopy (ZF) procedures remain uncertain. METHODS: We conducted a systematic review and meta-analysis comparing ZF ablation procedures guided by ICE vs. conventional techniques regarding efficacy and safety outcomes. PubMed, Cochrane, and embase were searched. A random-effects model was used to calculate risk ratios (RRs), odds ratios (OR) and mean differences (MDs) with 95% confidence intervals (CI). RESULTS: We includedfourteen studies with 1,919 patients of whom 1,023 (58.72%) performed ZF ablation using ICE. We found a significant reduced ablation time (SMD -0.18; 95% CI -0.31;-0.04; p=0.009), procedure time (MD -7.54; 95% CI -14.68;-0.41; p=0.04), fluoroscopic time (MD -2.52; 95% CI -3.20;-1.84; p<0.001) in patients treated with ZF approach compared with NZF approach. However, there was no significant difference between the two groups in acute success rate (RR 1.00; 95% CI 0.99-1.01; p=0.85), long-term success rate (RR 0.99; 95% CI 0.93-1.05; p=0.77) and complications (RR 0.84, 95% CI: 0.48-1.46; p = 0.54). CONCLUSION: Our findings suggest that among patients undergoing arrhythmia ablation, fluoroscopy-free ICE-guided technique reduces procedure time and radiation exposure with comparable short and long-term success rates and complications.


Assuntos
Fluoroscopia
14.
BMC Pulm Med ; 24(1): 108, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438922

RESUMO

BACKGROUND: Safely implementing transbronchial lung cryobiopsy (TBLC) in patients with interstitial lung disease (ILD) requires accurate navigation. Traditional fluoroscopy falls short in reducing the risk of post-procedure pneumothorax. The potential of electromagnetic navigation bronchoscopy (ENB) as a more precise navigation method warrants further exploration. METHODS: A prospective cohort study was conducted on ILD patients undergoing TBLC. Patients were assigned either fluoroscopy or ENB for cryoprobe positioning. Navigation accuracy was evaluated using cone beam computed tomography (CBCT) images as the standard. Safety and diagnostic yield were also observed. RESULTS: Seventeen patients underwent TBLC, with 10 guided by fluoroscopy and seven by ENB. Fluoroscopy-guided cryoprobe navigation required more adjustments [9/15 (60%) v.s. 1/9 (11%), p = 0.018] for subsequent TBLC compared to ENB, as confirmed by CBCT images. Clinical characteristics, post-procedure complications, and biopsy specimen size showed no significant differences between the groups. Fourteen patients obtained a pathological diagnosis, and 15 received a multidisciplinary discussion (MDD) diagnosis. In the fluoroscopy group, three patients failed to obtain a pathological diagnosis, and two failed to obtain an MDD diagnosis. CONCLUSIONS: ENB demonstrates significantly superior accuracy in TBLC navigation compared to traditional fluoroscopy when CBCT images are used as a reference. Further studies are necessary to determine the value of ENB in TBLC navigation for ILD patients.


Assuntos
Broncoscopia , Doenças Pulmonares Intersticiais , Humanos , Estudos Prospectivos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Fluoroscopia , Pulmão/diagnóstico por imagem , Fenômenos Eletromagnéticos
15.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475148

RESUMO

Ensuring precise angle measurement during surgical correction of orientation-related deformities is crucial for optimal postoperative outcomes, yet there is a lack of an ideal commercial solution. Current measurement sensors and instrumentation have limitations that make their use context-specific, demanding a methodical evaluation of the field. A systematic review was carried out in March 2023. Studies reporting technologies and validation methods for intraoperative angular measurement of anatomical structures were analyzed. A total of 32 studies were included, 17 focused on image-based technologies (6 fluoroscopy, 4 camera-based tracking, and 7 CT-based), while 15 explored non-image-based technologies (6 manual instruments and 9 inertial sensor-based instruments). Image-based technologies offer better accuracy and 3D capabilities but pose challenges like additional equipment, increased radiation exposure, time, and cost. Non-image-based technologies are cost-effective but may be influenced by the surgeon's perception and require careful calibration. Nevertheless, the choice of the proper technology should take into consideration the influence of the expected error in the surgery, surgery type, and radiation dose limit. This comprehensive review serves as a valuable guide for surgeons seeking precise angle measurements intraoperatively. It not only explores the performance and application of existing technologies but also aids in the future development of innovative solutions.


Assuntos
Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/métodos , Fluoroscopia/métodos
16.
Phys Med ; 120: 103324, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458105

RESUMO

PURPOSE: During any radiological procedure, it is important to know the dose to be-administered to the patient and this can be done by estimating the output of the X-ray tube either with a dosimeter or with a mathematical equation or Monte Carlo simulations. The aim of this work is to develop a new mathematical model equation (NMME) for estimating the output of high-frequency X-ray tubes. METHODS: To achieve this, data collected from ten machines in many regions of Cameroon were used (for nine machines) to build an initial model that does not take into account the anode angle and the tenth machine was used to test the model. Using the SpekCalc software, some simulations were carried out to evaluate the influence of the anode angle. This allowed the NMME to be proposed. RESULTS: The deviations frequencies between 0.65% and 19.61% were obtained by comparing the output values obtained using initial model with the measured values. The statistical hypothesis test showed that the estimated values using initial model and NMME are in agreement with those measured unlike the Kothan and Tungjai model. For the tenth machine, the percentage difference between estimated and measured values is less than 8 %. CONCLUSION: These results show that the proposed model performed better than the previous models. In the absence of a dosimeter, the NMME could be used to estimate the output of high frequency X-ray machines and therefore the radiation doses received by patients during diagnostic X-ray examinations.


Assuntos
Modelos Teóricos , Software , Humanos , Raios X , Fluoroscopia , Radiografia , Método de Monte Carlo , Doses de Radiação
17.
Phys Med ; 120: 103330, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38522409

RESUMO

OBJECTIVES: To evaluate the effect of equipment technology on reference point air kerma (Ka,r), air kerma-area product (PKA), and fluoroscopic time for fluoroscopically-guided gastrointestinal endoscopic procedures and establish benchmark levels. METHODS: This retrospective study included the consecutive patients who underwent fluoroscopically-guided gastrointestinal endoscopic procedures from May 2016 to August 2023 at a tertiary care hospital in the U.S. Fluoroscopic systems included (a) Omega CS-50 e-View, (b) GE Precision 500D, and (c) Siemens Cios Alpha. Radiation dose was analyzed for four procedure types of endoscopic retrograde biliary, pancreas, biliary and pancreas combined, and other guidance. Median and 75th percentile values were computed using software package R (version 4.0.5, R Foundation). RESULTS: This large study analyzed 9,459 gastrointestinal endoscopic procedures. Among four procedure types, median Ka,r was 108.8-433.2 mGy (a), 70-272 mGy (b), and 22-55.1 mGy (c). Median PKA was 20.9-49.5 Gy∙cm2 (a), 13.4-39.7 Gy∙cm2 (b), and 8.91-20.9 Gy∙cm2 (c). Median fluoroscopic time was 2.8-8.1 min (a), 3.6-9.2 min (b), and 2.9-9.4 min (c). Their median value ratio (a:b:c) was 8.5:4.8:1 (Ka,r), 2.7:2.1:1 (PKA), and 1.0:1.1:1 (fluoroscopic time). Median value and 75th percentile are presented for Ka,r, PKA, and fluoroscopic time for each procedure type, which can function as benchmark for comparison for dose optimization studies. CONCLUSION: This study shows manifold variation in doses (Ka,r and PKA) among three fluoroscopic equipment types and provides local reference levels (50th and 75th percentiles) for four gastrointestinal endoscopic procedure types. Besides procedure type, imaging technology should be considered for establishing diagnostic reference level. SUMMARY: With manifold (2 to 12 times) variation in doses observed in this study among 3 machines, we recommend development of technology-based diagnostic reference levels for gastrointestinal endoscopic procedures.


Assuntos
Níveis de Referência de Diagnóstico , Radiografia Intervencionista , Humanos , Estudos Retrospectivos , Doses de Radiação , Radiografia Intervencionista/métodos , Fluoroscopia/métodos
18.
Phys Med ; 120: 103338, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38554638

RESUMO

INTRODUCTION: This study investigates if inexpensive computer hardware, open-source computer vision and a phosphor screen from disused CR (computed radiography) Cassette can be used to quantitatively assess beam shape and area. MATERIALS AND METHODS: The phosphor screen was affixed to a Carestream CS 8100 dental OPG system and the camera was mounted above the X-ray tube. Videos were acquired of the green light emissions during the tomographic irradiation. Images of a chessboard pattern, attached to the detector were used to correct for camera angulation and provide image pixel size calibration. K-Means colour clustering was used to define beam area. The effect of light conditions on beam dimension measurement was also investigated. The beam width measurement from optimised methodology was compared with that determined from dose calibrated GAFChromicTM XR-SP2film. RESULTS: Videos in dark conditions provided the most reproducible results. FW20M gained from initial sampling matched that obtained using the GAFChromicTM film within the errors of the measurements,6.41 ± 0.09 mm FW20M from this methodology,compared with FW20M (full width at 20 % of maximum) 6.4 ± 0.1 mm from film. The height and area were 126 ± 0.22 mm and 807 ± 11 mm2 respectively. The chess pattern imaging provided a robust means of perspective correction and pixel calibration. There is potential for this methodology to be employed using any digital camera, provided the camera acquisition settings remain constant, the sensor pixels are square, and the camera position is fixed. CONCLUSION: The potential of this low-cost open-source method of beam area measurement using computer vision is thus proven.


Assuntos
Fluoroscopia , Imagens de Fantasmas
20.
J Bras Pneumol ; 50(1): e20230290, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38536983

RESUMO

OBJECTIVE: To evaluate the combined impact of videofluoroscopic swallow study (VFSS) and therapeutic feeding and swallowing interventions on clinical outcomes in children with oropharyngeal dysphagia (OPD). METHODS: This was an uncontrolled longitudinal analytical study in which OPD patients were evaluated before and after VFSS. Children ≤ 24 months of age diagnosed with OPD in a clinical setting and undergoing VFSS for investigation and management of OPD were included in the study. The study participants received therapeutic feeding and swallowing interventions after having undergone VFSS, being followed at an outpatient clinic for pediatric dysphagia in order to monitor feeding and swallowing difficulties. Respiratory and feeding outcomes were compared before and after VFSS. RESULTS: Penetration/aspiration events were observed in 61% of the VFSSs (n = 72), and therapeutic feeding and swallowing interventions were recommended for 97% of the study participants. After the VFSS, there was a reduction in the odds of receiving antibiotic therapy (OR = 0.007) and in the duration of antibiotic therapy (p = 0.014), as well as in the odds of being admitted to hospital (p = 0.024) and in the length of hospital stay (p = 0.025). A combination of oral and enteral feeding became more common than oral or enteral feeding alone (p = 0.002). CONCLUSIONS: A high proportion of participants exhibited penetration/aspiration on VFSS. Therapeutic feeding and swallowing interventions following a VFSS appear to be associated with reduced respiratory morbidity in this population.


Assuntos
Transtornos de Deglutição , Deglutição , Humanos , Criança , Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Fluoroscopia , Aspiração Respiratória/etiologia , Aspiração Respiratória/complicações , Antibacterianos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...